Draeger XXS Replacement Sensors
Sensor: Phosphine (PH3) - 6810886
Multiple units or setup help
Need several of these or help choosing a setup? Chat with FSS.
Couldn't load pickup availability
Four different DrägerSensor XXS parts: PH3 6810886, NO 6811545, standard NO2 6810884 and NO2 LC 6812600. They are not interchangeable, and a replacement sensor does not convert a monitor to another gas. Choose the number printed on the sensor installed in your instrument.
Shipping & state availability
ShippingShips within the contiguous United States. Shipping to Alaska and Hawaii is not available.

Product Details
PH3 sensor (Dräger 6810886)
Phosphine (PH3) replacement sensor 6810886, sensor range 0–20 ppm. Sensor only: match the part number in your instrument.
- Sensor and range
- Phosphine (PH3)
- Sensor range: 0–20 ppm
- Not for
- Other gases
- Dräger order code
- 6810886
- Included
- One sensor only
- Fit limits
- Dräger lists this part for the Pac 8000, X-am 5000, X-am 5600, X-am 5800 and X-am 8000.
- Dräger does not list the X-am 2800 for this part.
- It is not PH3 HC sensor 6812020.
- Replaceable, but not Plug & Play: Dräger requires adjustment when this sensor is replaced.
- Installation and calibration are separate and are not included.
- Confirm with FSS
- The calibration interval for your instrument.
What you need for this setup
- Installed sensor part number matchBefore ordering.
- Calibration after installationNot included.
NO sensor (Dräger 6811545)
Replacement nitric oxide (NO) sensor 6811545. Sensor only: match the part number installed in your instrument.
- Sensor and range
- Nitric oxide (NO)
- Sensor range: 0–200 ppm
- Not for
- Nitrogen dioxide (NO2)
- Nitrous oxide (N2O)
- Dräger order code
- 6811545
- Included
- One sensor only
- Fit limits
- Dräger lists this part for the Pac 8000, X-am 5000, X-am 5600, X-am 5800 and X-am 8000.
- Dräger does not list the X-am 2800 for this part.
- This is the sensor range. Dräger lists the finished Pac 8000 NO monitor at 0–50 ppm.
- Replaceable, but not Plug & Play: Dräger requires adjustment when this sensor is replaced.
- Installation and calibration are separate and are not included.
What you need for this setup
- Installed sensor part number matchBefore ordering.
- Installation and calibration by a qualified providerNot included.
Standard NO2 sensor (Dräger 6810884)
Standard NO2 replacement sensor 6810884 for the X-am instruments Dräger lists. Different part from NO2 LC 6812600.
- Sensor and range
- Nitrogen dioxide (NO2), standard sensor
- Sensor range: 0–50 ppm
- Not for
- Nitric oxide (NO)
- Nitrous oxide (N2O)
- Dräger order code
- 6810884
- Included
- One sensor only
- Fit limits
- Dräger lists this part for the X-am 2500, X-am 2800, X-am 3500, X-am 5000, X-am 5600, X-am 5800 and X-am 8000. Its sheet also lists the X-am 2600, footnoted "device accepts the sensor".
- Pac 8000 compatibility is not confirmed by the Dräger sheet reviewed, and an older overview differs. That does not make it incompatible. Check the part installed in your Pac.
- It is not a substitute for NO2 LC sensor 6812600.
- Replaceable, but not Plug & Play: Dräger requires adjustment when this sensor is replaced.
- Installation and calibration are separate and are not included.
What you need for this setup
- Installed sensor part number matchBefore ordering.
- Installation and calibration by a qualified providerNot included.
NO2 LC sensor (Dräger 6812600)
NO2 LC replacement sensor 6812600 for Pac 8000, X-am 5000 and 5800. Not a substitute for standard NO2 sensor 6810884.
- Sensor and range
- Nitrogen dioxide (NO2), LC sensor
- Sensor range: 0–50 ppm
- Not for
- Nitric oxide (NO)
- Nitrous oxide (N2O)
- Dräger order code
- 6812600
- Included
- One sensor only
- Fit limits
- Dräger lists this part for the Pac 8000, X-am 5000, X-am 5600, X-am 5800 and X-am 8000.
- Dräger does not list the X-am 2800 for this part.
- It is not an upgrade from, or a substitute for, the standard NO2 sensor.
- Replaceable, but not Plug & Play: Dräger requires adjustment when this sensor is replaced.
- Installation and calibration are separate and are not included.
What you need for this setup
- Installed sensor part number matchBefore ordering.
- Installation and calibration by a qualified providerNot included.
Product Overview
DrägerSensor XXS replacement sensors are available for PH3, NO, NO2 and NO2 LC. Match the Dräger part number already installed in your instrument; these sensors are not interchangeable. Each option includes one sensor. Installation and calibration are separate.
Key Features
- Choose the part number on your installed sensor
- PH3 6810886, NO 6811545, NO2 6810884, NO2 LC 6812600
- Not interchangeable; instrument fit differs by part
- One sensor per order
- Adjustment required after replacement; not included
More product information
Order the DrägerSensor XXS replacement that matches the part number already installed in your instrument. These four sensors are different parts and are not interchangeable. Select a sensor to see its gas, sensor range, instrument list and price.
- Phosphine (PH3), 6810886: Sensor range 0–20 ppm. Dräger lists it for the Pac 8000, X-am 5000, X-am 5600, X-am 5800 and X-am 8000. It is not PH3 HC sensor 6812020.
- Nitric oxide (NO), 6811545: Sensor range 0–200 ppm. Dräger lists it for the Pac 8000, X-am 5000, X-am 5600, X-am 5800 and X-am 8000. A finished monitor can have a different range: Dräger lists the Pac 8000 NO monitor at 0–50 ppm.
- Nitrogen dioxide (NO2), standard, 6810884: Sensor range 0–50 ppm. Dräger lists it for the X-am 2500, X-am 2800, X-am 3500, X-am 5000, X-am 5600, X-am 5800 and X-am 8000. Its sheet also lists the X-am 2600, footnoted "device accepts the sensor". The Dräger sheet reviewed does not confirm Pac 8000 compatibility, so check the part installed in your Pac.
- Nitrogen dioxide (NO2 LC), 6812600: Sensor range 0–50 ppm. Dräger lists it for the Pac 8000, X-am 5000, X-am 5600, X-am 5800 and X-am 8000. It is not an upgrade from, or a substitute for, standard NO2 sensor 6810884.
What it does not do
- Each sensor measures only the gas listed for it. NO is a different gas from nitrogen dioxide (NO2) and nitrous oxide (N2O).
- NO 6811545, standard NO2 6810884 and NO2 LC 6812600 are not interchangeable.
- A replacement sensor does not convert a monitor to a different gas.
- These sensors are replaceable, but they are not Plug & Play.
What arrives
- One sensor only, matching the order number you select. No instrument, test gas or installation.
What you need separately
- An instrument that already uses this part number.
- Installation and adjustment. Dräger requires adjustment when an XXS sensor is replaced.
- Suitable test gas. For PH3 6810886, Dräger lists about 0.2 to 18 ppm PH3, such as 0.5 ppm test gas 4597057. For NO2 LC 6812600, Dräger lists 5 ppm NO2 in nitrogen as the Pac 8000 calibration gas.
Testing and service
- FSS offers PH3 instrument calibration: FSS monitor calibration service.
- FSS calibration service covers standard four-gas and PH3 instruments only, so NO and NO2 work needs a qualified provider.
Specifications
- 6810886: Phosphine (PH3), sensor range 0–20 ppm
- 6811545: Nitric oxide (NO), sensor range 0–200 ppm
- 6810884: Nitrogen dioxide (NO2), sensor range 0–50 ppm
- 6812600: Nitrogen dioxide (NO2 LC), sensor range 0–50 ppm
Replacement parts
- This is the replacement part. Order the number printed on the sensor already installed in your instrument.
Manuals and help
- Documents: DrägerSensor & Portable Instruments Handbook, 7th edition (9046571); DrägerSensor XXS PH3 instructions (9023920); Dräger Pac 6x00/8x00 technical manual (9033742).
- Need help choosing or setting up? Use Chat with FSS on this page or contact FSS.
Testing, service and accessories
- Service: For an instrument with this sensor, you can request FSS PH3 calibration service.
- Draeger Calibration Gas Cylinders / Phosphine (PH3) 0.5 ppm 58 L - 4597057: After installation the instrument is tested with 0.5 ppm PH3 in nitrogen.
- Service: FSS calibration service covers standard four-gas and PH3 instruments only, so it does not cover NO or NO2.
- Service: FSS calibration service covers standard four-gas and PH3 instruments only, so it does not cover NO or NO2.
- Service: FSS calibration service covers standard four-gas and PH3 instruments only, so it does not cover NO or NO2.
Need help with your application?
FSS helps commercial grain and food-handling facilities with equipment selection, setup and application planning.