Draeger
Draeger X-am 5800 Four-Gas Monitor VN01703
Selected: O2 / LEL / CO / H2S / Battery only - existing charger required
Multiple units or setup help
Need multiple monitors or help choosing a setup? Chat with FSS.
Lead time varies by configuration and manufacturer availability.
Couldn't load pickup availability
Choose your setup
Starts at one charging set per monitor. Change it if you need fewer or none.
Total
Shipping & state availability
ShippingShips within the contiguous United States. Shipping to Alaska and Hawaii is not available.

Product Details
X-am 5800 Four-Gas (Dräger VN01703)
Four-gas X-am 5800: LEL, O2, CO and H2S. No PH3 channel. NiMH battery installed; no charger is listed for this configuration.
- Measures
- Oxygen (O2)
- Combustible gas (LEL)
- Carbon monoxide (CO)
- Hydrogen sulfide (H2S)
- Does not measure
- Phosphine (PH3). This configuration has no PH3 channel.
- Dräger order code
- VN01703
- Included
- X-am 5800 with installed sensors
- NiMH battery 3703887, installed
- Use what you already own
- Compatible X-am charging equipment, if you already have it
- Battery & charging
- NiMH battery 3703887 is installed. Dräger's configuration listing names no charger. Charging set 8320333 is a charging module and power supply, with no battery.
- Confirm with FSS
- The regulator, tubing, connectors and vent hose for in-house testing.
- The full packing list for VN01703, if you need it before ordering.
What you need for this setup
- Draeger X-am Desktop Charging Sets / Charger + power supply, no battery - 8320333 Order no. 8320333Needed if you do not already own a compatible chargerSkip if you already own compatible X-am charging equipment.
- Inlet line from regulator to adapterOnly for in-house testing with 8318752.Ask FSS about the inlet tube
- Vent hose on the second adapter connectorOnly for in-house calibration with 8318752.Ask FSS about the vent hose
- Access to bump testing and calibration for all four gasesYour own supplies, an existing station or a service route can meet this.
Product Overview
The Dräger X-am 5800 VN01703 is a portable personal gas monitor set up for four gases: combustible gas (%LEL), oxygen (O2), carbon monoxide (CO) and hydrogen sulfide (H2S). It has no phosphine (PH3) channel.
Its NiMH battery is installed, but Dräger's configuration listing names no charger. Add charging set 8320333 unless you already own compatible X-am charging equipment, and plan how you will bump test and calibrate all four gases.
Key Features
- Dräger configuration VN01703: %LEL, O2, CO and H2S
- No phosphine (PH3) channel
- NiMH battery 3703887 installed
- Charger not listed: add 8320333 or use compatible equipment you own
- Test gas, regulator and adapter sold separately
More product information
What it does not do
- Does not measure phosphine (PH3) or any gas beyond these four.
- A reading alone does not clear a space for entry or re-entry. Follow your site procedures, permit system and any applicable label.
What arrives
- X-am 5800 with CatEx SR sensor 6851900, O2 PR sensor 6800530 and dual CO/H2S sensor 6813280.
- NiMH battery 3703887, installed.
- Dräger's configuration listing names no charger.
What you need separately
- A charger: add charging set 8320333 (charging cradle and power supply) unless you already own compatible X-am charging equipment.
- Bump-test and calibration access for all four gases.
Testing and service
- Dräger lists calibration adapter 8318752 and four-gas test gas 4594655 for the X-am 5800, at 0.5 L/min. Its manual calls for a hose on the adapter's second connector to vent calibration gas to an exhaust or outdoors.
- The regulator, inlet tube and vent hose are not included and the complete part list is being confirmed, so ask FSS before relying on a manual setup.
- FSS offers calibration for standard four-gas instruments: FSS monitor calibration service.
Specifications
- Dräger order number: VN01703
- Combustible gas: CatEx SR 6851900: 0–100 %LEL
- Oxygen: O2 PR 6800530: 0–30 vol.%
- CO and H2S: Dual sensor 6813280: CO 0–2,000 ppm, H2S 0–100 ppm
- Battery: NiMH 3703887, installed
- Manual test flow: 0.5 L/min
Replacement parts
- Rechargeable battery 3703887.
- Sensors: match the number on the installed sensor.
Manuals and help
- Documents: Dräger X-am 2600/2800/5800 technical manual (9300310); Dräger X-am 5800 product information (DMC-113184).
- Need help choosing or setting up? Use Chat with FSS on this page or contact FSS.
Common questions
Does VN01703 detect phosphine? No. It has no PH3 channel. For phosphine, look at the X-am 5000 five-gas option or the Pac 8000 PH3 monitor.
Do I need the charging set? Only if you do not already own compatible X-am charging equipment. If you choose the monitor-plus-charging option, VN01703 and 8320333 are added as two separate items.
Testing, service and accessories
- Testing: Dräger lists four-gas test gas 4594655 and calibration adapter 8318752 for the X-am 5800.
- Service: For the standard four gases, you can request FSS calibration service.
- Add only if needed: External sampling pump, hose and filter
- Draeger Manual Fixed-Flow Regulators 0.5 L/min / Standard - 4557020: Standard 0.5 L/min manual regulator, a candidate for the four-gas cylinder.
- Draeger Manual Fixed-Flow Regulators 0.5 L/min / Stainless steel - 6813104: Stainless 0.5 L/min manual regulator, a candidate for the four-gas cylinder.
- Draeger Four-Gas Manual Calibration Kit 4511330: Dräger describes a four-gas calibration kit. FSS can confirm the supplied parts and whether it suits your monitor.
- FSS calibration service, standard four-gas: FSS calibration is confirmed for the standard four gases.
Need help with your application?
FSS helps commercial grain and food-handling facilities with equipment selection, setup and application planning.