Dräger Pac 8000 PH3 image. Regional labeling or packaging can differ; order number VN01566 governs.
Dräger Pac 8000 CO2 image. Regional labeling or packaging can differ; order number VN01557 governs.
Dräger Pac 8000 NH3 image. Regional labeling or packaging can differ; order number VN01560 governs.
Dräger Pac 8000 Cl2 image. Regional labeling or packaging can differ; order number VN01556 governs.
Dräger Pac 8000 O3 image. Regional labeling or packaging can differ; order number VN01565 governs.
Draeger
Draeger Pac 8000 Single-Gas Monitors
Gas: Phosphine (PH3) - VN01566
Multiple units or setup help
Need multiple monitors or help choosing a setup? Chat with FSS.
Lead time varies by configuration and manufacturer availability.
Lead time varies by configuration and manufacturer availability.
Lead time varies by configuration and manufacturer availability.
Lead time varies by configuration and manufacturer availability.
Lead time varies by configuration and manufacturer availability.
Couldn't load pickup availability
Single-gas monitor: detects only the selected gas.
Shipping & state availability
ShippingShips within the contiguous United States. Shipping to Alaska and Hawaii is not available.

Product Details
Pac 8000 PH3 monitor (Dräger VN01566)
Pac 8000 PH3 monitor VN01566: 0–20 ppm, Bluetooth version. A complete single-gas monitor that measures only PH3.
- Measures
- Phosphine (PH3) only
- Measuring range: 0–20 ppm
- Bluetooth version
- Does not measure
- Oxygen, combustible gas and all other gases
- Dräger order code
- VN01566
- Included
- One Pac 8000 PH3 monitor with installed battery
- Battery & charging
- Uses a replaceable battery installed in the monitor. No charger is needed.
What you need for this setup
- Access to PH3 bump testing and calibrationYour own supplies, an existing station or a service route can meet this. X-dock is not the only route.
Pac 8000 CO2 monitor (Dräger VN01557)
Pac 8000 CO2 monitor VN01557: 0–5 vol.%, Bluetooth version. A complete single-gas monitor that measures only CO2.
- Measures
- Carbon dioxide (CO2) only
- Measuring range: 0–5 vol.%
- Bluetooth version
- Does not measure
- Oxygen (O2). A CO2 monitor does not measure oxygen
- Combustible gas and all other gases
- Dräger order code
- VN01557
- Included
- One Pac 8000 CO2 monitor with installed battery
- Battery & charging
- Uses a replaceable battery installed in the monitor. No charger is needed.
- Confirm with FSS
- The regulator, tubing, connectors and outlet handling for CO2 testing.
What you need for this setup
- CO2 test gas and delivery partsOnly if you test in-house. Skip if you use another testing route.Ask FSS about CO2 test gas
- Access to CO2 bump testing and calibrationFSS calibration does not cover this gas. A qualified provider, your own supplies or a station can meet this.
Pac 8000 NH3 monitor (Dräger VN01560)
Pac 8000 NH3 monitor VN01560: 0–300 ppm, Bluetooth version. A complete single-gas monitor that measures only NH3.
- Measures
- Ammonia (NH3) only
- Measuring range: 0–300 ppm
- Bluetooth version
- Does not measure
- Oxygen, combustible gas and all other gases
- Dräger order code
- VN01560
- Included
- One Pac 8000 NH3 monitor with installed battery
- Battery & charging
- Uses a replaceable battery installed in the monitor. No charger is needed.
- Confirm with FSS
- The regulator, tubing, connectors and outlet handling for NH3 testing.
What you need for this setup
- NH3 test gas and delivery partsOnly if you test in-house. Skip if you use another testing route.Ask FSS about NH3 test gas
- Access to NH3 bump testing and calibrationFSS calibration does not cover this gas. A qualified provider, your own supplies or a station can meet this.
Pac 8000 Cl2 monitor (Dräger VN01556)
Pac 8000 Cl2 monitor VN01556: 0–20 ppm, Bluetooth version. A complete single-gas monitor that measures only Cl2.
- Measures
- Chlorine (Cl2) only
- Measuring range: 0–20 ppm
- Bluetooth version
- Does not measure
- Chlorine dioxide (ClO2)
- Oxygen, combustible gas and all other gases
- Dräger order code
- VN01556
- Included
- One Pac 8000 Cl2 monitor with installed battery
- Battery & charging
- Uses a replaceable battery installed in the monitor. No charger is needed.
- Confirm with FSS
- The regulator, tubing, connectors and outlet handling for Cl2 testing.
What you need for this setup
- Cl2 test gas and delivery partsOnly if you test in-house. Skip if you use another testing route.Ask FSS about Cl2 test gas
- Access to Cl2 bump testing and calibrationFSS calibration does not cover this gas. A qualified provider, your own supplies or a station can meet this.
Pac 8000 O3 monitor (Dräger VN01565)
Pac 8000 O3 monitor VN01565: 0–10 ppm, Bluetooth version. A complete single-gas monitor that measures only O3.
- Measures
- Ozone (O3) only
- Measuring range: 0–10 ppm
- Bluetooth version
- Does not measure
- Oxygen, combustible gas and all other gases
- Dräger order code
- VN01565
- Included
- One Pac 8000 O3 monitor with installed battery
- Battery & charging
- Uses a replaceable battery installed in the monitor. No charger is needed.
What you need for this setup
- O3 test gas and delivery partsOnly if you test in-house. Skip if you use another testing route.Ask FSS about O3 test gas
- Access to O3 bump testing and calibrationFSS calibration does not cover this gas. A qualified provider, your own supplies or a station can meet this.
Product Overview
The Dräger Pac 8000 is a personal single-gas monitor, Bluetooth version, with an installed, replaceable battery. Choose the gas you need to monitor: phosphine (PH3), carbon dioxide (CO2), ammonia (NH3), chlorine (Cl2) or ozone (O3). Each monitor measures only the gas you select.
Key Features
- Five gas options: PH3, CO2, NH3, Cl2 or O3
- Installed, replaceable battery; no charger needed
- IP68 housing, about 106 g without clip
- Test gas and test accessories sold separately
- FSS calibration service covers the PH3 monitor
More product information
Dräger Pac 8000 single-gas monitors, Bluetooth version, in five gas options: PH3 VN01566, CO2 VN01557, NH3 VN01560, Cl2 VN01556 and O3 VN01565. Each is a complete personal monitor with an installed, replaceable battery.
What it does not do
- A CO2 monitor does not measure oxygen. Where carbon dioxide can displace oxygen, measure oxygen separately.
- The chlorine option is for Cl2, not chlorine dioxide (ClO2).
- A replacement sensor does not convert a Pac 8000 to a different gas.
- A gas monitor does not replace your site's safety procedures, training or hazard assessment.
What arrives
- One Pac 8000 monitor for the option you select, with its battery installed.
- No charger is needed. The battery is replaceable and is not recharged.
What you need separately
- Access to bump testing and calibration for the selected gas.
- Test gas and its regulator, tubing and outlet handling, if you test in-house. Confirm the gas path with FSS.
- Bluetooth app and cloud services, such as Dräger Gas Detection Connect, which are licensed separately.
Specifications
- PH3 VN01566: 0–20 ppm
- CO2 VN01557: 0–5 vol.%
- NH3 VN01560: 0–300 ppm
- Cl2 VN01556: 0–20 ppm
- Ozone VN01565: 0–10 ppm
- Size without clip: 64 x 84 x 20 mm
- Device weight: about 106 g, or 113 g with clip
- Protection rating: IP68
Manuals and help
- Documents: Dräger Pac 8000 product information (DMC-113257); Dräger Pac 6x00/8x00 technical manual (9033742).
- Need help choosing or setting up? Use Chat with FSS on this page or contact FSS.
Testing, service and accessories
- Testing: Dräger's Pac manual calls for 0.5 ppm PH3 in nitrogen for in-house testing. Confirm the regulator, hose, connectors and outlet handling with FSS.
- Service: For this monitor, you can request FSS PH3 calibration service.
- Optional Pac communication module 8318587 includes a USB cable for computer configuration and data downloads. Sold separately.
- FSS calibration service is available for this PH3 monitor.
- Optional Pac manual bump-test station 8317410 is sold without a gas cylinder. The test gas and delivery parts must match the selected monitor.
- Replacement sensor grid 8326852 is available for the Pac 8000 when the grid needs replacing.
- 0.5 ppm PH3 test gas (cylinder 4597057) matches the in-house test gas in the Pac manual. It is not yet available to order online.
- Replacement battery 8326856 is not yet available to order online. Ask FSS if you need one.
- Testing: Dräger lists calibration adapter 8318588 and communication module 8318587 for the Pac. CO2 test gas and its delivery parts are separate.
- Service: FSS calibration service covers standard four-gas and PH3 instruments only, so CO2 needs a qualified provider.
- Optional Pac communication module 8318587 includes a USB cable for computer configuration and data downloads. Sold separately.
- Optional Pac manual bump-test station 8317410 is sold without a gas cylinder. The test gas and delivery parts must match the selected monitor.
- Replacement sensor grid 8326852 is available for the Pac 8000 when the grid needs replacing.
- Replacement battery 8326856 is not yet available to order online. Ask FSS if you need one.
- Testing: Dräger lists calibration adapter 8318588 and communication module 8318587 for the Pac. Its calibration chart calls for Tygon tubing and a stainless-steel regulator for NH3.
- Service: FSS calibration service covers standard four-gas and PH3 instruments only, so NH3 needs a qualified provider.
- Optional Pac communication module 8318587 includes a USB cable for computer configuration and data downloads. Sold separately.
- Optional Pac manual bump-test station 8317410 is sold without a gas cylinder. The test gas and delivery parts must match the selected monitor.
- Replacement sensor grid 8326852 is available for the Pac 8000 when the grid needs replacing.
- Replacement battery 8326856 is not yet available to order online. Ask FSS if you need one.
- Testing: Dräger lists calibration adapter 8318588 and communication module 8318587 for the Pac. Its calibration chart calls for a stainless-steel regulator and PTFE-lined tubing for Cl2.
- Service: FSS calibration service covers standard four-gas and PH3 instruments only, so Cl2 needs a qualified provider.
- Optional Pac communication module 8318587 includes a USB cable for computer configuration and data downloads. Sold separately.
- Optional Pac manual bump-test station 8317410 is sold without a gas cylinder. The test gas and delivery parts must match the selected monitor.
- Replacement sensor grid 8326852 is available for the Pac 8000 when the grid needs replacing.
- Replacement battery 8326856 is not yet available to order online. Ask FSS if you need one.
- Testing: Follow the instructions for your instrument and use a qualified service provider for ozone testing.
- Service: FSS calibration service covers standard four-gas and PH3 instruments only, so O3 needs a qualified provider.
- Optional Pac communication module 8318587 includes a USB cable for computer configuration and data downloads. Sold separately.
- Calibration adapter 8318588 fits the Pac 8000. Confirm the ozone test route with FSS before ordering it.
- Optional Pac manual bump-test station 8317410 is sold without a gas cylinder. The test gas and delivery parts must match the selected monitor.
- Replacement sensor grid 8326852 is available for the Pac 8000 when the grid needs replacing.
- Replacement battery 8326856 is not yet available to order online. Ask FSS if you need one.
Need help with your application?