Draeger
Draeger Calibration Adapters for X-am and Pac 8000
Instrument: X-am 1/2/5x00 cradle - 8318752
Multiple units or setup help
Need several of these or help choosing a setup? Chat with FSS.
Couldn't load pickup availability
Shipping & state availability
ShippingShips within the contiguous United States. Shipping to Alaska and Hawaii is not available.

Product Details
X-am calibration adapter (Dräger 8318752)
Cradle 8318752 holds an X-am for manual gas testing and PC communication. Gas, regulator and hoses are separate. Not a charger.
- Fits
- X-am 1/2/5x00 instruments
- Not for
- Charging: it is not a charger
- Dräger order code
- 8318752
- Included
- One adapter
- Fit limits
- A PC connection also needs USB DIRA interface 8317409.
- Confirm with FSS
- The regulator, inlet tube, connectors and vent hose for your test setup.
- For PH3 testing, which regulator applies.
What you need for this setup
- Draeger Manual Fixed-Flow Regulators 0.5 L/min / Standard - 4557020 Order no. 4557020Only if you test in-house. Skip if you use another testing route.Ask FSS which regulator fits
- Draeger Manual Fixed-Flow Regulators 0.5 L/min / Stainless steel - 6813104 Order no. 6813104Only if you test in-house. Skip if you use another testing route.Ask FSS which regulator fits
- Inlet tube and vent hose for 8318752Ask FSS about the inlet tube and vent hose
- Compatible X-am 1/2/5x00 instrumentCustomer-owned or bought separately.
- Test gas matched to your monitor’s sensorsChoose four-gas test gas, PH3 test gas or both, by your monitor’s channels.
Pac calibration adapter (Dräger 8318588)
Pac calibration adapter 8318588 for manual gas testing, listed in Dräger's Pac 8000 information. Gas, regulator and tubing are separate.
- Fits
- Pac 8000
- Not for
- PC connection: this adapter has no USB cable
- Dräger order code
- 8318588
- Included
- One adapter
- Fit limits
- No USB cable is included.
- Dräger also lists communication module 8318587, with USB cable, for PC connection and manual bump testing or calibration.
- X-dock is not the only route for Pac testing.
- Confirm with FSS
- The regulator, tubing, connectors and outlet connection for your test setup.
What you need for this setup
- Draeger Manual Fixed-Flow Regulators 0.5 L/min / Standard - 4557020 Order no. 4557020Only if you test in-house. Skip if you use another testing route.Ask FSS which regulator fits
- Draeger Manual Fixed-Flow Regulators 0.5 L/min / Stainless steel - 6813104 Order no. 6813104Only if you test in-house. Skip if you use another testing route.Ask FSS which regulator fits
- Gas line and outlet connection for 8318588Ask FSS about tubing and outlet handling
- Pac 8000 instrumentCustomer-owned or bought separately.
Product Overview
Dräger calibration adapters for manual gas testing at 0.5 L/min: X-am cradle 8318752 for X-am 1/2/5x00 instruments, including the X-am 5000 and X-am 5800, or Pac adapter 8318588 for the Pac 8000. Each option is one adapter. Test gas, a 0.5 L/min regulator and tubing are separate; confirm them with FSS before ordering.
Key Features
- X-am cradle 8318752 or Pac adapter 8318588
- Choose the adapter for your instrument
- Used at 0.5 L/min for manual testing
- Gas, regulator and tubing not included
- Confirm the gas path with FSS
More product information
Choose the Dräger calibration adapter for your instrument. Each one holds the monitor so test gas can be applied by hand at 0.5 L/min. It is one part of a test setup, not a complete kit. Select an option to see its fit, order number and price.
- X-am cradle, order number 8318752: The calibration cradle, also called the calibration adapter, for X-am 1/2/5x00 instruments, including the X-am 5000 and X-am 5800.
- Pac adapter, order number 8318588: The Pac calibration adapter listed in Dräger's Pac 8000 product information, for manual bump testing and calibration.
What it does not do
- Neither option is a complete test setup: gas, regulator and tubing are separate.
- X-am cradle 8318752 is not a charger. A PC connection also needs USB DIRA interface 8317409, which is not included.
- Pac adapter 8318588 has no USB cable and is not a PC connection. Communication module 8318587 includes a USB cable and can also be used for manual bump testing and calibration.
What arrives
- One calibration cradle or adapter, matching the order number you select.
What you need separately
- Test gas for the channels you are testing, such as 0.5 ppm PH3 gas 4597057 for a Pac 8000 PH3.
- A 0.5 L/min regulator and tubing. Confirm the regulator, tubing and outlet connection with FSS first.
- For X-am cradle 8318752, a hose on the cradle's second connector for venting during calibration. Dräger names no part for it, so ask FSS.
Testing and service
- Dräger's X-am manuals use cradle 8318752 at 0.5 L/min and vent calibration gas to a fume cupboard, exhaust or the open air.
- Dräger's Pac manual calls for 0.5 L/min, and for span calibration a stable reading after at least 120 seconds. X-dock is not the only route for Pac testing.
- These are testing accessories; no service is included.
Specifications
- 8318752 instruments: X-am 1/2/5x00
- 8318588 instrument: Pac 8000
- Manual test flow: 0.5 L/min
- 8318752 PC link: Also needs USB DIRA 8317409
- 8318588 span calibration wait: Stable reading, at least 120 seconds
Replacement parts
- None listed by FSS.
Manuals and help
- Documents: Dräger X-am 5000 technical manual (9023999); Dräger X-am 2600/2800/5800 technical manual (9300310); Dräger Pac 6x00/8x00 technical manual (9033742); Dräger Pac 8000 product information (DMC-113257); Dräger calibration gases brochure (DMC-106176).
- Need help choosing or setting up? Use Chat with FSS on this page or contact FSS.
Testing, service and accessories
- Draeger Four-Gas Manual Calibration Kit 4511330: Dräger describes a four-gas calibration kit. FSS can confirm the supplied parts before you order.
- Draeger Calibration Gas Cylinders / Phosphine (PH3) 0.5 ppm 58 L - 4597057: The adapter needs a test gas. The Pac manual calls for 0.5 ppm PH3 in nitrogen.
Need help with your application?
FSS helps commercial grain and food-handling facilities with equipment selection, setup and application planning.



