Draeger
Draeger Methyl Bromide 0.1/a Detector Tubes - 10/Box
Commercial & Bulk Pricing
Need case or pallet quantities? Chat with FSS about volume pricing.
Couldn't load pickup availability
Shipping & state availability
Shipping unavailableAK, HI, DC, WA, WV

Product Overview
Dräger Methyl Bromide 0.1/a Detector Tubes are colorimetric tubes for determining whether methyl bromide is present in air at the sampling point over the time the sample is drawn. Each box contains 10 single-use measurement units for use with a compatible Dräger tube pump.
Each result is a selective spot measurement. Select the measurement method and sampling procedure according to the current fumigant label, applicator manual, Fumigation Management Plan, site requirements, and the instructions supplied with the tube and pump. A tube reading is not a determination of clearance, re-entry authorization, worker safety, or regulatory compliance.
More product information
Measurement Ranges
Dräger Methyl Bromide 0.1/a (order no. 3706301)
0.1 to 5 ppm at 10 strokes, with a measuring time of approximately 5 minutes; or 5 to 50 ppm at 2 strokes, with a measuring time of approximately 1 minute. These are two separate measurement methods. Color change: light to green. Permissible ambient conditions (Dräger): 2 to 40 °C, humidity no more than 40 mg H₂O/L. Standard deviation: ±15 to 20%.
Specifications
- Measures: Methyl bromide in air
- Dräger order number: 3706301
- Package quantity: 10 single-use measurement units
- Pump: Dräger tube pumps, including the accuro manual bellows pump
- Method: Selective spot measurement; use only a range and stroke count printed in the tube instructions
Use Notes
Before each measurement, perform the required pump leak test with an unused tube.
Perchloroethylene or trichloroethylene prevents a methyl bromide measurement. Other substances can affect the indication. Review the current instructions for complete cross-sensitivity, handling, storage, and disposal information.
What's Included
One box of 10 Dräger Methyl Bromide 0.1/a measurement units. Tube pump sold separately.
Storage & Expiry
Store within the limits printed on the package. Do not use after the expiration date. Dispose of used or expired tubes according to applicable local requirements.
Need help with your application?
FSS helps commercial grain and food-handling facilities with equipment selection, setup and application planning.